26 lines
3.2 KiB
Markdown
26 lines
3.2 KiB
Markdown
- [x] (1) fix vertical lines to small to be seen: in some cases (e.g. rect waveform in @mock_upstreamer.py) the vertical lines are to thin to be visible (sometime they glitch in and out of existence):
|
|
1. the antialisaing strategy with phosphore effect should be applied with more stregth
|
|
2. the lines should be more tick
|
|
3. the sample points should be bigger
|
|
- [x] (2) ~~relative timing~~ **done**: `--relative-time`; see README and SPECS.md for the measured history cost.
|
|
- in order to avoid problem with time jitter user can decide to go in relative time mode
|
|
- in this mode absolute signal time is only use for export
|
|
- the plot time depends just on signal sample rate and frame number, e.g.:
|
|
- user is acquiring a signal with 1MSps and 100_000 samples per udp frame
|
|
- last frame as number <N> and previous <N-2> in this case a 100_000 indexes must be skipped
|
|
- time is simply: `((<N_frame> - <N_last>) * <n_samples_per_frame> - <sample_index>) / <sample rate>` (or something like that)
|
|
- [x] (3) ~~named configurations~~ **done**: one directory per source holding `<name>.toml` per configuration plus `active`; a configuration carries a note and the startup settings (`buffer_mb`, `relative_time`, `capture_packets`); the chooser lists them and the menu's _Configurations…_ opens/saves/deletes them.
|
|
- [x] (4) ~~optional udp frame storage for debugging of strange behaviours~~ **done**: `--capture-packets N`; see README and the design note in `docs/superpowers/specs/` for the ring file, the popover toggle and `tools/capture_to_pcap.py`.
|
|
- [x] (5) ~~open exported binary waveforms to view/analyse~~ **done**: `--open FILE` and the chooser's **Waveforms** page (the files opened before, newest first, plus *Open…*); the `.npy`'s dtype names the columns, so a load restores the signals, the samples and the axis the export had, and every instrument works on it — see README and `docs/claude/invariants-data-path.md`.
|
|
- [x] (6) ~~imporve right click menu on the plots~~ **done**: the plot's context menu uses the main menu's row style (`menu_button` + `.udpscope-menu`, asserted by `UDPSCOPE_PROBE_ROWMENU_MS`: uniform `label_x=26`, `h=18`, the shortcut flush right), and deleting a signal is a **Remove signal** submenu listing that plot's traces plus _All traces on this plot_.
|
|
- [ ] (7) in layout edit mode add the option to drag plot border to resize them
|
|
- [x] (8) ~~add option to automatic save the last <N> triggered acquisitions in a cache folder and let the user replay them~~ **done**: every latch is written to `<cache>/<source>/events/` as a `.npy` (the export format), a `.txt` sidecar and a `.bmp` preview drawn from the samples; the **events pane** (revealed with trigger mode, switchable) lists them with time, duration, signals and rate, shows the preview, replays one through the `--open` loader and has *Live* to go back -- see README and `docs/claude/invariants-trigger-and-pinning.md`.
|
|
- [ ] (9) preferences dialog:
|
|
- user can choose evnt cache directory (default <home>/.cache/udpscope/<source>/events/)
|
|
- maximum number of events to cache
|
|
- disable completly the events storage option
|
|
- enable/disable relative time mode
|
|
- interface dark/light/auto color
|
|
- defaults
|
|
- other parameters
|