3.2 KiB
3.2 KiB
- (1) fix vertical lines to small to be seen: in some cases (e.g. rect waveform in @mock_upstreamer.py) the vertical lines are to thin to be visible (sometime they glitch in and out of existence):
- the antialisaing strategy with phosphore effect should be applied with more stregth
- the lines should be more tick
- the sample points should be bigger
- (2)
relative timingdone:--relative-time; see README and SPECS.md for the measured history cost.- in order to avoid problem with time jitter user can decide to go in relative time mode
- in this mode absolute signal time is only use for export
- the plot time depends just on signal sample rate and frame number, e.g.:
- user is acquiring a signal with 1MSps and 100_000 samples per udp frame
- last frame as number and previous in this case a 100_000 indexes must be skipped
- time is simply:
((<N_frame> - <N_last>) * <n_samples_per_frame> - <sample_index>) / <sample rate>(or something like that)
- (3)
named configurationsdone: one directory per source holding<name>.tomlper configuration plusactive; a configuration carries a note and the startup settings (buffer_mb,relative_time,capture_packets); the chooser lists them and the menu's Configurations… opens/saves/deletes them. - (4)
optional udp frame storage for debugging of strange behavioursdone:--capture-packets N; see README and the design note indocs/superpowers/specs/for the ring file, the popover toggle andtools/capture_to_pcap.py. - (5)
open exported binary waveforms to view/analysedone:--open FILEand the chooser's Waveforms page (the files opened before, newest first, plus Open…); the.npy's dtype names the columns, so a load restores the signals, the samples and the axis the export had, and every instrument works on it — see README anddocs/claude/invariants-data-path.md. - (6)
imporve right click menu on the plotsdone: the plot's context menu uses the main menu's row style (menu_button+.udpscope-menu, asserted byUDPSCOPE_PROBE_ROWMENU_MS: uniformlabel_x=26,h=18, the shortcut flush right), and deleting a signal is a Remove signal submenu listing that plot's traces plus All traces on this plot. - (7) in layout edit mode add the option to drag plot border to resize them
- (8)
add option to automatic save the last triggered acquisitions in a cache folder and let the user replay themdone: every latch is written to<cache>/<source>/events/as a.npy(the export format), a.txtsidecar and a.bmppreview drawn from the samples; the events pane (revealed with trigger mode, switchable) lists them with time, duration, signals and rate, shows the preview, replays one through the--openloader and has Live to go back -- see README anddocs/claude/invariants-trigger-and-pinning.md. - (9) preferences dialog:
- user can choose evnt cache directory (default /.cache/udpscope//events/)
- maximum number of events to cache
- disable completly the events storage option
- enable/disable relative time mode
- interface dark/light/auto color
- defaults
- other parameters