Files
udpscope/help/C/org.udpscope.app/measurements.page
T
Martino Ferrari 22e7a8efcc measure: the split's own means are back as above/below/between
`top`, `bottom` and `amplitude` became the *flat levels* in e83ad86 -- the level the
signal dwells at, read from the density of the window's buckets -- and that change kept
the split's own two means as its internal fallback for a window the pyramid cannot
summarize. Those means are now three types of their own, so the two different questions
about one split can be asked side by side: `above %` and `below %` are the plain mean of
the samples on one side of a share -- the reading the old `top`/`bottom` gave -- and
`between % %` is the mean of the band between two shares, which no single split can
answer, because a band's two edges are two thresholds.

Nothing about the arithmetic is new, and nothing is a new pass. `Above`/`Below` are the
`sum[]`/`count[]` split `measure_accumulate()` already folds -- the very figures
`Top`/`Bottom` fall back to -- and `Between` is the **difference of two levels' upper
sides**, both of which come out of one pass two over one window. It rides the bucket
fast path unchanged: a bucket wholly inside the band is strictly above the lower level
and strictly below the upper one, so both accumulators fold it whole, and only the
buckets that straddle either edge are opened. `measure_level_pcts()` is the one place the
shares are read, and it clamps both and puts `between`'s pair **in order**, so "between
80 % and 20 %" is the band between 20 % and 80 % -- normalized rather than refused,
because the shares name two edges rather than a direction. Nothing to measure reads `--`,
as for every other type: a share at 100 % has no sample above it, and a band can hold
none at all.

Measured, `[bandavg-probe]`, fast mock at a 2 s window (`--rate 1300000 --batch 1000
--freq 1`):

  sine   `above 50` 0.636620 (2/pi), `below 50` -0.636620, `between 50 75` 0.255873
  square `above 50` 0.986496 (30 harmonics) / 1.000000 (--square-harmonics 0),
         `between 50 75` 0.302744 / --
  ramp   `between 50 75` 0.250000 and `above 50` 0.500000, `above 100` --

The first three are the figures the old `top`/`bottom` documented; the ramp's are what a
uniform density predicts (a band's mean is its own centre); the ideal square's empty band
is the nothing-to-measure rule. The pane offers the types and edits their percentages
through the dialog's second share -- which only `between` shows -- and a measurement's
pair survives add/edit/delete and the session file (`threshold2`), where a file written
before it existed loads at the default.

No raw pass: with the measurements probe adding one of every type at a 2 s window, `raw`
went from 113966 of 240719031 covered (0.0%) to 134978 of 255372033 (0.1%), 0.8 -> 1.1
ns a covered sample.

Docs: the band-average invariant (and the two assertions the flat-level change moved),
the probe readings for the new probe, the verification recipe, the manual's measurements
page and the README.
2026-10-15 07:56:37 +02:00

150 lines
10 KiB
Plaintext

<page xmlns="http://projectmallard.org/1.0/"
type="topic" style="task"
id="measurements">
<info>
<link type="guide" xref="index#analysis"/>
<link type="seealso" xref="cursors"/>
<desc>A measurement is a statistic of the visible window of one signal, with optional
on-plot marks and a per-measurement statistics line.</desc>
<credit type="author copyright">
<name>Martino Ferrari</name>
</credit>
</info>
<title>Measurements</title>
<p>A measurement is a statistic of the <em>visible window</em> of one signal, recomputed as
that window moves. The pane lists them with their values; each can also draw its result on
the plot.</p>
<section id="reach">
<title>How to reach it</title>
<steps>
<item>
<p>Press the measurements button in the toolbar, or <key>m</key>.</p>
</item>
<item>
<p>The pane's <gui>+</gui> adds one; clicking a row opens the dialog where the signal,
the type, the threshold share or shares and the on-plot marks are set, with
<gui>Save</gui> and <gui>Delete</gui>.</p>
</item>
</steps>
</section>
<section id="knowing">
<title>Worth knowing</title>
<list>
<item><p>The types are average, top, bottom, min, max, peak to peak, amplitude, above,
below, between, pulse duration, period and frequency. <gui>top</gui> and <gui>bottom</gui> are the waveform's
<em>flat</em> high and low levels: the level the signal dwells at, taken from the densest
band of the window on each side of the split. A band-limited edge overshoots and rings —
a nominal 2 V square reaches about ±1.18 at its edges — and a ripple or an overshoot is
therefore <em>not</em> what these read. <gui>amplitude</gui> is the delta between those two
levels, and <gui>peak to peak</gui> is the swing between the extremes (so on a rippled
square <gui>amplitude</gui> reads 2 V where <gui>peak to peak</gui> reads 2.36 V).</p></item>
<item><p><gui>above</gui>, <gui>below</gui> and <gui>between</gui> are the opposite kind of
number: the plain <em>mean of the samples</em> above a share, below it, or between two
shares. That is a different question from <gui>top</gui>/<gui>bottom</gui> even about the
same split, and it is the older one — on a unit sine <gui>above 50%</gui> reads 0.64 V
(2/π, the mean of a half cycle) where <gui>top</gui> reads 0.96 V (near the peak, which is
where a sine dwells most), and on a band-limited square <gui>above 50%</gui> reads 0.99 V
where <gui>top</gui> reads the plateau, 1.00 V: the edge's ring is inside the first and not
inside the second. <gui>between</gui> takes <em>two</em> shares — <gui>from %</gui> and
<gui>to %</gui> — and reports the mean of the samples inside that band, which no single
split can answer; the order you type them in does not matter, since a band between 80 % and
20 % is the band between 20 % and 80 %.</p></item>
<item><p>A mean over a side carries whatever is on that side, so these three are the right
numbers when you want the <em>energy</em> or the <em>offset</em> of part of the waveform,
and the wrong ones when you want the level a plateau sits at. Like every other measurement,
one with nothing to measure reads <code>--</code> rather than a made-up number: a share at
100 % has no sample above it, and a band can hold none at all — on an ideal
(non-ringing) square every sample is exactly ±1, so a band between 50 % and 75 % is
empty.</p></item>
<item><p><gui>top</gui> and <gui>bottom</gui> also read <em>near the peak</em> on a
waveform that has no flat part, which is the honest reading rather than a failure: a unit
sine has no plateau, so the densest band is at its peak and these read about ±0.96 — not
the 0.64 a mean over each half would give, and not ±1 either. Only a level the signal
actually dwells at is a level.</p></item>
<item><p>The <em>split</em> says which side a level is read from, so any share between the
two levels reads the same number; it is not a boundary the value depends on. The one case
where it is read directly is a window the scope cannot summarize by level — a window
shorter than a level's own resolution, or one read through <gui>hf</gui> — where
<gui>top</gui>/<gui>bottom</gui> fall back to the mean of each side of the split and
<gui>amplitude</gui> to the window's peak to peak.</p></item>
<item><p>The on-plot marks come in two kinds and the mix is the reading: a <em>level</em>
mark is a ruler at a value, a <em>time</em> mark is a marker at a position. An average
draws one level mark; a max draws a level mark <em>and</em> a time mark at the first
sample that reached it; <gui>peak to peak</gui> draws a ruler at each extreme and
<gui>amplitude</gui> a ruler at each of its two flat levels — the pair is the span, so
the two rulers <em>are</em> the measurement.</p></item>
<item><p>Marks cannot be dragged. A measurement mark says what the measurement measured,
so it is created unselectable — as is the trigger marker.</p></item>
<item><p>A pass is throttled to a cadence rather than run every frame, so a ruler over a
live view is <em>stepped</em>. The number and the ruler come from the same pass, so they
always agree.</p></item>
<item><p>An invalid pass keeps its <em>level</em> marks and drops its <em>time</em>
marks. A level is a property of the signal and outlives the window; a position inside
the window does not. That is what stops the rulers blinking off at a mode change.</p></item>
<item><p>A crossing is counted with <em>hysteresis</em>, not on a bare level: the
thresholds are a tenth of the window's peak to peak either side of the share, and an
edge is counted only once the signal has passed the far one. Period, frequency and pulse
duration all depend on it. The mid level is exactly where a waveform moves fastest, so
any interferer faster than the fundamental recrosses a single level several times per
real crossing — a 5 Hz sine with a 500 Hz tone at a tenth of the amplitude reads 39 Hz
without the band and 5 Hz with it. The band holds to an interferer a third of the
waveform's own size.</p></item>
<item><p>The band is clamped to stay inside the data, which is what keeps a threshold set
near an extreme usable: a fixed band there would sit above every sample and the
measurement would read nothing. A share near an extreme still leaves the band little
room, so it rejects less — which is one reason period and frequency offer no share to
set.</p></item>
<item><p>A window with too few crossings reads <code>invalid</code> / <code>--</code>
rather than a plausible invented number. Frequency over a window holding one edge is the
usual case.</p></item>
<item><p><gui>frequency</gui> is reported in Hz and <gui>period</gui>/<gui>pulse
duration</gui> in seconds; every other type carries the channel's own unit. A value is
written with a <em>metric prefix</em> so its digits sit in <code>1..999</code> —
<code>636.62 mV</code>, not <code>0.64 V</code> — including when the stream declares no
unit at all, which is always the case for a math channel: there the prefix goes tight
against the number (<code>636.62m</code>), since two decimals of an unprefixed small
value is <code>0.00</code>.</p></item>
<item><p>Cost is bounded by reading the summary pyramid the producer already maintains,
not the raw window: a bucket's sum is a sum, so the mean, the extremes and a level's own
mean are exact. <gui>top</gui>, <gui>bottom</gui> and <gui>amplitude</gui> read the
<em>density</em> of the window out of that same summary — which is what tells a flat level
from a ripple — so those three cost a second read of the summary and never of a sample, and
<gui>between</gui>'s second share is one more level in the same summary walk rather than a
walk of its own.</p></item>
<item><p><gui>Statistics</gui> adds a second line to every measurement showing
<code>n</code>, the mean, the standard deviation and the range. Each observation is one
<em>recompute</em> of the pane, so <code>n</code> counts windows measured, not samples —
a mean frequency over many windows is what that claims to be. <gui>Reset</gui> clears
every accumulator and starts fresh. A change of display window, a CONFIG or a
measurement edit also resets; a pause, a resume, a zoom, a pan and the toggle itself do
not, so turning the line off to read the plot and back on again keeps the history.</p></item>
</list>
</section>
<section id="example">
<title>Example</title>
<p>On a 1 Hz ±1 sine: <code>average=0</code>, <code>top=0.957988</code>,
<code>bottom=-0.957988</code> (the flat levels, near the peaks — a sine has no plateau),
<code>max=1</code>, <code>min=-1</code>,
<code>peak to peak=2</code>, <code>amplitude=1.915983</code>, <code>pulse duration=0.5 s</code>
(duty 0.5), <code>period=1 s</code>, <code>frequency=1 Hz</code>. On the same stream's
band-limited <code>square</code>, whose edges ring out to ±1.179: <code>top=0.999983</code>,
<code>bottom=-0.999983</code>, <code>amplitude=1.999966</code> against
<code>peak to peak=2.358701</code> — the levels are the plateau's and the extremes are the
edges'. Over a 2 M-sample window those passes read about 0.1% of the samples.</p>
<p>The mean-over-a-side types on the same two windows: on the sine
<code>above 50=0.636620</code>, <code>below 50=-0.636620</code> and
<code>between 50 75=0.255873</code>; on the rippled square <code>above 50=0.986496</code> and
<code>between 50 75=0.302744</code>, against <code>1.000000</code> for the same
<code>above 50</code> on an ideal (non-ringing) square. A <code>ramp</code>, whose density is
uniform, is the shape that names what a band mean <em>is</em>: <code>above 50=0.500000</code>
and <code>between 50 75=0.250000</code>, each band's own centre.</p>
</section>
</page>