03b63ba03a
Full implementation of Laguerre-Gauss modal reconstruction for gyrotron beam diagnostics, per the approved design spec, plus tests, docs, and a runnable end-to-end example. Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
105 lines
6.2 KiB
Markdown
105 lines
6.2 KiB
Markdown
# CLAUDE.md
|
|
|
|
This file provides guidance to Claude Code (claude.ai/code) when working with code in this repository.
|
|
|
|
## What this is
|
|
|
|
`he11lib` reconstructs the Laguerre-Gauss (LG) modal content ("mode purity") of a
|
|
free-space-propagating gyrotron RF beam from a set of thermal (flux) images taken at
|
|
different distances from the output window. It accounts for camera geometry (unknown
|
|
pixel scale / oblique viewing angle), sensor noise, target thermal-diffusion blur, and
|
|
unknown beam center/pointing.
|
|
|
|
The full design rationale lives in
|
|
`docs/superpowers/specs/2026-07-02-gyrotron-mode-purity-design.md` — read it before
|
|
making architectural changes. `docs/api.md` is the API reference for the implemented
|
|
public interface; keep it in sync when changing public signatures.
|
|
|
|
## Commands
|
|
|
|
```bash
|
|
pip install -e ".[dev]" # editable install with test dependencies (numpy, scipy, matplotlib, pytest)
|
|
pytest # run the full test suite (discovers tests/, per pyproject.toml)
|
|
pytest tests/test_modes.py # run one test file
|
|
pytest tests/test_modes.py::test_field_at_waist # run one test
|
|
python examples/full_pipeline_example.py # runnable end-to-end demo
|
|
```
|
|
|
|
There is a project `.venv`; activate it or otherwise ensure the editable install's
|
|
dependencies are available before running tests.
|
|
|
|
`tests/conftest.py` forces the `Agg` matplotlib backend so plotting tests run headless.
|
|
|
|
This project is not (yet) a git repository.
|
|
|
|
## Architecture
|
|
|
|
Data flows through the pipeline as a list of `MeasurementPlane` (one per imaging
|
|
distance `z`), each holding a raw 2D `flux` array plus optionally-known
|
|
`pixel_scale`/`viewing_angle_deg`. Everything downstream is keyed off `LGBasis`, which
|
|
defines the mode basis relative to a known waist `w0`/`z0`/`wavelength`.
|
|
|
|
Module responsibilities (`he11lib/`):
|
|
|
|
- **`data.py`** — `MeasurementPlane`, `ReconstructionResult` (the shared input/output
|
|
types) and `validate_planes` (>=3 planes, matching shapes, distinct `z`).
|
|
- **`modes.py`** — `LGBasis`: closed-form paraxial LG fields, beam radius `w(z)`,
|
|
Gouy phase, inverse radius of curvature, and projection of a measured field onto a
|
|
candidate mode set. This is the analytic ground truth all fitting is checked against.
|
|
- **`geometry.py`** — `GeometryCalibration`: resolves a plane's pixel-to-physical
|
|
coordinate grid, deferring to known `pixel_scale`/`viewing_angle_deg` on the plane
|
|
over any override passed in.
|
|
- **`noise.py`** — `NoiseEstimator`: automatic per-image noise-std estimation
|
|
(Laplacian method) and per-pixel weights for noise-weighted least squares.
|
|
- **`deconvolution.py`** — `DiffusionDeconvolver`: optional forward blur / Wiener
|
|
deconvolution for thermal-diffusion blur in the absorbing target. The blur kernel is
|
|
isotropic in pixel space, so it's only exact when `viewing_angle_deg == 0` (an
|
|
oblique view makes x/y pixel scales differ) — an accepted approximation, not a bug.
|
|
- **`synthetic.py`** — `SyntheticBeamGenerator`: forward model that produces
|
|
`MeasurementPlane`s from known ground-truth coefficients/center/pointing/geometry.
|
|
Used throughout the test suite and examples to validate the pipeline end-to-end.
|
|
- **`fitting.py`** — `ModalFitter` (`fit`, `fit_auto`) and `generate_mode_shells`: the
|
|
core joint nonlinear least-squares fit (complex LG coefficients + beam
|
|
center/pointing + unknown geometry) via `scipy.optimize.least_squares`. `fit_auto`
|
|
grows the candidate mode set shell-by-shell (by order `2p + |l|`), stopping via a BIC
|
|
improvement threshold, capped at `max_order` (emits `UserWarning`, doesn't raise, if
|
|
still improving at the cap).
|
|
- **`phase_retrieval.py`** — `propagate_angular_spectrum` (FFT-based paraxial
|
|
free-space propagation) and `PhaseRetriever` (multi-plane Gerchberg-Saxton), the
|
|
fallback reconstruction path for when a finite mode basis doesn't fit well.
|
|
- **`reconstruct.py`** — `BeamReconstructor`: the orchestrator. Pipeline order:
|
|
validate planes → optional deconvolution (requires known `pixel_scale` per plane) →
|
|
`ModalFitter.fit_auto` → optional `PhaseRetriever` fallback (forced via
|
|
`force_phase_retrieval`, or triggered automatically when the noise-weighted RMS
|
|
residual exceeds `phase_retrieval_residual_threshold`). The fallback path projects
|
|
the recovered field onto all modes up to `max_order` and produces a
|
|
`ReconstructionResult` with `used_phase_retrieval=True`, empty `residuals`, and NaN
|
|
`coefficient_uncertainty` (no fit covariance available from phase retrieval).
|
|
- **`plotting.py`** — diagnostic figures (`plot_mode_purity`, `plot_center_trace`,
|
|
`plot_residuals`); each returns a `Figure` rather than calling `plt.show()`.
|
|
|
|
Everything above is re-exported from the top-level `he11lib` package (see
|
|
`he11lib/__init__.py`); import from there rather than submodules.
|
|
|
|
## Known physics/fitting pitfalls (read before writing new tests or examples)
|
|
|
|
These aren't library bugs — they're consequences of realistic optics parameters and of
|
|
automatic order-selection being genuinely data-driven — but they've caused most of the
|
|
debugging time in this project's history:
|
|
|
|
1. **Rayleigh-range / frame clipping.** `w(z)` grows with `|z - z0|` relative to
|
|
`zR = pi*w0**2/wavelength`. With typical test parameters (`w0=5e-3`,
|
|
`wavelength=1.76e-3`), `zR` is only ~4.46 cm, so z-distances spanning tens of cm put
|
|
the beam many Rayleigh ranges out, where `w(z)` can exceed a small test frame —
|
|
clipping the beam and corrupting fits, or introducing FFT wraparound artifacts in
|
|
`propagate_angular_spectrum`. Keep z-distances within roughly ±1-2 Rayleigh ranges of
|
|
`z0`, or enlarge the frame/pixel_scale accordingly.
|
|
2. **Automatic mode-set growth can overfit deconvolution artifacts.** Wiener-deconvolved
|
|
data always has some residual imperfection; `fit_auto`'s BIC-driven growth will try
|
|
to "explain" it with spurious higher-order modes, degrading fitted beam
|
|
center/pointing via parameter degeneracy (observed: pointing angle off by 4-6x at
|
|
`max_order=3` vs. matching ground truth almost exactly at `max_order=1`, for the same
|
|
2-mode ground truth). When demonstrating growth with deconvolution or noise, set
|
|
`max_order` close to the true expected mode content rather than generously high,
|
|
unless the test specifically targets growth behavior itself.
|