Files
ec-gn-ja-pcf/EC-GN-JA-PCF/.svn/pristine/aa/aad892fd0db0322af5975ea3a79ee406a924ac2e.svn-base

350 lines
7.6 KiB
Plaintext

record (bo,"EC-GN-P01-GPF:PCF4210-CTRP")
{
field(DESC, "Fast Controller Fault")
field(ONAM, "ON")
field(PINI, "YES")
field(SCAN, "Passive")
field(SIML, "EC-GN-P01-GAF:STAT-DO-SIMM")
field(VAL, "0")
field(ZNAM, "OFF")
}
record (bo,"EC-GN-P01-GPF:PCF4210-YTS-GA1")
{
field(DESC, "GY1 HV Armed")
field(ONAM, "ON")
field(PINI, "YES")
field(SCAN, "Passive")
field(SIML, "EC-GN-P01-GAF:STAT-DO-SIMM")
field(VAL, "0")
field(ZNAM, "OFF")
}
record (bo,"EC-GN-P01-GPF:PCF4210-YTS-GA2")
{
field(DESC, "GY1 HV Injection")
field(ONAM, "ON")
field(PINI, "YES")
field(SCAN, "Passive")
field(SIML, "EC-GN-P01-GAF:STAT-DO-SIMM")
field(VAL, "0")
field(ZNAM, "OFF")
}
record (bo,"EC-GN-P01-GPF:PCF4210-YTS-GA3")
{
field(DESC, "GY1 in RFON")
field(ONAM, "ON")
field(PINI, "YES")
field(SCAN, "Passive")
field(SIML, "EC-GN-P01-GAF:STAT-DO-SIMM")
field(VAL, "0")
field(ZNAM, "OFF")
}
record (bo,"EC-GN-P01-GPF:PCF4210-YTS-GB1")
{
field(DESC, "GY2 HV Armed")
field(ONAM, "ON")
field(PINI, "YES")
field(SCAN, "Passive")
field(SIML, "EC-GN-P01-GBF:STAT-DO-SIMM")
field(VAL, "0")
field(ZNAM, "OFF")
}
record (bo,"EC-GN-P01-GPF:PCF4210-YTS-GB2")
{
field(DESC, "GY2 HV Injection")
field(ONAM, "ON")
field(PINI, "YES")
field(SCAN, "Passive")
field(SIML, "EC-GN-P01-GBF:STAT-DO-SIMM")
field(VAL, "0")
field(ZNAM, "OFF")
}
record (bo,"EC-GN-P01-GPF:PCF4210-YTS-GB3")
{
field(DESC, "GY2 RFON")
field(ONAM, "ON")
field(PINI, "YES")
field(SCAN, "Passive")
field(SIML, "EC-GN-P01-GBF:STAT-DO-SIMM")
field(VAL, "0")
field(ZNAM, "OFF")
}
record (bi,"EC-GN-P01-GPF:PSU0000-YSTA-MOD")
{
field(DESC, "MHVPS modulation en/disable from ECPC")
field(DTYP, "asynInt32")
field(INP, "@asyn(ni6528_1, 8) bitread")
field(ONAM, "ENABLE")
field(PINI, "YES")
field(SCAN, "I/O Intr")
field(SIML, "EC-GN-P01-GAF:STAT-DI-SIMM")
field(VAL, "0")
field(ZNAM, "DISABLE")
}
record (bo,"EC-GN-P01-GPF:STAT-DAQ-CONF-STAT")
{
field(DESC, "DAQ config state")
field(ONAM, "Ready")
field(PINI, "YES")
field(SCAN, "Passive")
field(VAL, "0")
field(ZNAM, "Not ready")
}
record (bo,"EC-GN-P01-GPF:STAT-DAQ-RECONF")
{
field(DESC, "Reset and configure DAQ")
field(HIGH, "0.1")
field(ONAM, "ON")
field(PINI, "YES")
field(SCAN, "Passive")
field(VAL, "0")
field(ZNAM, "OFF")
}
record (bo,"EC-GN-P01-GPF:STAT-DAQ-SW-TRIG")
{
field(DESC, "software trigger for DAQ start")
field(HIGH, "0.1")
field(ONAM, "ON")
field(PINI, "YES")
field(SCAN, "Passive")
field(VAL, "0")
field(ZNAM, "OFF")
}
record (bo,"EC-GN-P01-GPF:STAT-RST-FLT")
{
field(DESC, "Reset Fault command")
field(HIGH, "0.1")
field(ONAM, "ON")
field(PINI, "YES")
field(SCAN, "Passive")
field(VAL, "0")
field(ZNAM, "OFF")
}
record (ao,"EC-GN-P01-GPF:STAT-DAQ-LEN")
{
field(DESC, "DAQ sampling time length")
field(DRVH, "3600000")
field(DRVL, "0.01")
field(EGU, "ms")
field(HOPR, "3600000")
field(LOPR, "0.01")
field(PINI, "YES")
field(PREC, "2")
field(SCAN, "Passive")
field(VAL, "1000.0")
}
record (ao,"EC-GN-P01-GPF:STAT-DAQ-LEN-RB")
{
field(DESC, "DAQ sampling time length readback")
field(DRVH, "3600000")
field(DRVL, "0.01")
field(EGU, "ms")
field(HOPR, "3600000")
field(LOPR, "0.01")
field(PINI, "YES")
field(PREC, "2")
field(SCAN, "Passive")
field(VAL, "1000.0")
}
record (mbbo,"EC-GN-P01-GPF:STAT-DAQ-MODE")
{
field(DESC, "DAQ mode")
field(FRST, "Reference")
field(FRVL, "4")
field(ONST, "Finite")
field(ONVL, "1")
field(PINI, "YES")
field(SCAN, "Passive")
field(THST, "Continuous")
field(THVL, "3")
field(TWST, "Retriggerable")
field(TWVL, "2")
field(VAL, "3")
field(ZRST, "Software_triggered")
field(ZRVL, "0")
}
record (mbbo,"EC-GN-P01-GPF:STAT-DAQ-MODE-RB")
{
field(DESC, "DAQ mode readback")
field(FRST, "Reference")
field(FRVL, "4")
field(ONST, "Finite")
field(ONVL, "1")
field(PINI, "YES")
field(SCAN, "Passive")
field(THST, "Continuous")
field(THVL, "3")
field(TWST, "Retriggerable")
field(TWVL, "2")
field(VAL, "3")
field(ZRST, "Software_triggered")
field(ZRVL, "0")
}
record (ao,"EC-GN-P01-GPF:STAT-DAQ-PUB-DLY")
{
field(DESC, "DAN publish delay")
field(DRVH, "1000")
field(DRVL, "0.1")
field(EGU, "ms")
field(HOPR, "1000")
field(LOPR, "0.1")
field(PINI, "YES")
field(PREC, "1")
field(SCAN, "Passive")
field(VAL, "10.0")
}
record (ao,"EC-GN-P01-GPF:STAT-DAQ-PUB-DLY-RB")
{
field(DESC, "DAN publish delay")
field(DRVH, "1000")
field(DRVL, "0.1")
field(EGU, "ms")
field(HOPR, "1000")
field(LOPR, "0.1")
field(PINI, "YES")
field(PREC, "1")
field(SCAN, "Passive")
field(VAL, "10.0")
}
record (longout,"EC-GN-P01-GPF:STAT-DAQ-SMPL-RATE")
{
field(DESC, "sampling rate")
field(DRVH, "1000000000")
field(DRVL, "1")
field(HOPR, "100000000")
field(LOPR, "1")
field(PINI, "YES")
field(SCAN, "Passive")
field(VAL, "1000")
}
record (longout,"EC-GN-P01-GPF:STAT-DAQ-SMPL-RATE-RB")
{
field(DESC, "sampling rate readback")
field(DRVH, "1000000000")
field(DRVL, "1")
field(HOPR, "100000000")
field(LOPR, "1")
field(PINI, "YES")
field(SCAN, "Passive")
field(VAL, "1000")
}
record (ao,"EC-GN-P01-GPF:STAT-DAQ-SMPL-ST-DLY")
{
field(DESC, "DAQ start delay")
field(DRVH, "3600000")
field(DRVL, "0.01")
field(EGU, "ms")
field(HOPR, "3600000")
field(LOPR, "0.01")
field(PINI, "YES")
field(PREC, "2")
field(SCAN, "Passive")
field(VAL, "1.0")
}
record (ao,"EC-GN-P01-GPF:STAT-DAQ-SMPL-ST-DLY-RB")
{
field(DESC, "DAQ start delay readback")
field(DRVH, "3600000")
field(DRVL, "0.01")
field(EGU, "ms")
field(HOPR, "3600000")
field(LOPR, "0.01")
field(PINI, "YES")
field(PREC, "2")
field(SCAN, "Passive")
field(VAL, "1.0")
}
record (mbbo,"EC-GN-P01-GPF:STAT-DAQ-STAT")
{
field(DESC, "DAQ operation state")
field(FRSV, "NO_ALARM")
field(ONST, "Waiting trigger")
field(ONVL, "1")
field(PINI, "YES")
field(SCAN, "Passive")
field(THST, "Error")
field(THSV, "MAJOR")
field(THVL, "3")
field(TWST, "Aquiring")
field(TWSV, "NO_ALARM")
field(TWVL, "2")
field(VAL, "3")
field(ZRST, "Not ready")
field(ZRSV, "NO_ALARM")
field(ZRVL, "0")
}
record (longin,"EC-GN-P01-GPF:STAT-MD1-LIM")
{
field(DESC, "MD1 Pulse Len Limit")
field(HOPR, "500000000")
field(LOPR, "0")
field(PINI, "YES")
field(SCAN, "Passive")
field(VAL, "10000")
}
record (longin,"EC-GN-P01-GPF:STAT-MD2-LIM")
{
field(DESC, "MD2 Pulse Len Limit")
field(HOPR, "500000000")
field(LOPR, "0")
field(PINI, "YES")
field(SCAN, "Passive")
field(VAL, "100000")
}
record (longin,"EC-GN-P01-GPF:STAT-MD3-LIM")
{
field(DESC, "MD3 Pulse Len Limit")
field(HOPR, "500000000")
field(LOPR, "0")
field(PINI, "YES")
field(SCAN, "Passive")
field(VAL, "30000000")
}
record (longin,"EC-GN-P01-GPF:STAT-MD4-LIM")
{
field(DESC, "MD4 Pulse Len Limit")
field(HOPR, "500000000")
field(LOPR, "0")
field(PINI, "YES")
field(SCAN, "Passive")
field(VAL, "300000000")
}
record (ai,"EC-GN-P01-GPF:STAT-RDY-TOUT")
{
field(DESC, "Gyrotron operation ready timeout")
field(EGU, "s")
field(HOPR, "600")
field(LOPR, "1")
field(PINI, "YES")
field(PREC, "1")
field(SCAN, "Passive")
field(VAL, "30.0")
}