Cursors read values off the traces. There are two kinds: one shared vertical pair that every row carries at the same time, and horizontal rulers, one pair per row, that belong to that row alone.
Press the cursors button in the header bar, or
The readings are in the dock (a read-only copy) and on the
The mode dropdown offers four modes:
The vertical pair is one time for the whole figure, so moving it on
any row moves it on all of them. That is what makes dt meaningful across
rows.
A ruler belongs to its row and nothing shares it, so two rows' rulers are independent. The plots of a split row are one row here: they share their y axis, so the rulers are at the same values in each.
A value is the nearest stored sample's, never a number between two samples. Zoom in past the sample spacing and the line between two samples is something the plot drew, not data — so a reading off it would be the drawing. The hover crosshair reads the same way.
Every reading carries a metric prefix so the digits sit in
1..999: 10.52 mV, not 0.01 V. Two decimals is all
an instrument landing on an f32 sample can claim, so without the prefix a
small value would read 0.00 and the reading would be gone. A stream that
declares no unit gets the prefix anyway, written tight against the number
(585.24m) — the space separates the number from its unit, and a spaced
m with nothing after it would read as metres.
A marker past the newest sample reads --. With only one marker
over data the row reads partial: a difference between a number and nothing
is not a number.
The hover crosshair also writes its two coordinates where the eye already
looks: the value where its horizontal line meets the y axis, and the time where its
vertical line meets the x axis — each in a small box among that axis' own tick labels,
in the axis' own format. Each box is centred on the line it names, and its background
covers what is behind it, so a tick label underneath never prints through the number.
The preference's
In a split row the horizontal line runs across every plot of the row, not just the one under the pointer: the plots share one y range, so it is one value along the whole row. It stops at the row's edges — another row has a scale of its own.
In
The time row exists only in the modes that show the vertical pair.
A cursor stays where you put it while a live view rolls under it,
which is what a bench scope does: its T0 is an age, so a marker left at
-1.5s keeps reading the sample a second and a half old as the stream
advances. A measurement's marks do the opposite — they travel with the sample they
measured — because a cursor is a question you asked and a mark is an answer about one
particular sample.
Three traces in sine 0.31 V -0.84 V -1.15 V. Move the second
marker past the newest sample and the third column reads --.