fix: a readout keeps its metric prefix when the stream declares no unit
The SI prefix ladder in format_measure() was gated on a non-empty unit, so two decimals of a small unitless value printed `0.00` -- the reading gone, not merely coarse. That is a whole class of channels rather than a corner: a CONFIG need not declare a unit, and a math channel never has one. Below 1e-12 the same loss happened even with a unit, so that range falls back to three significant digits. With no unit the prefix goes tight against the number (`585.24m`), since the space exists to separate the number from its unit and a spaced `m` alone reads as metres. The mock declared `unit="V"` for every data signal, which is why no probe could see this; it now takes `--unit ''`. Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
This commit is contained in:
1 parent
3d7e214295
commit
b505706d92
6 files changed
+66
-25
No files matched your search
@@ -27,7 +27,11 @@ set, with <b>Save</b> and <b>Delete</b>.
|
||||
• A window with too few crossings reads <tt>invalid</tt> / <tt>--</tt> rather than a plausible
|
||||
invented number. Frequency over a window holding one edge is the usual case.
|
||||
• <tt>frequency</tt> is reported in Hz and <tt>period</tt>/<tt>pulse duration</tt> in seconds;
|
||||
every other type carries the channel's own unit.
|
||||
every other type carries the channel's own unit. A value is written with a <i>metric prefix</i>
|
||||
so its digits sit in <tt>1..999</tt> — <tt>636.62 mV</tt>, not <tt>0.64 V</tt> — including when
|
||||
the stream declares no unit at all, which is always the case for a math channel: there the
|
||||
prefix goes tight against the number (<tt>636.62m</tt>), since two decimals of an unprefixed
|
||||
small value is <tt>0.00</tt>.
|
||||
• Cost is bounded by reading the summary pyramid the producer already maintains, not the raw
|
||||
window. The values are still exact: a bucket's sum is a sum.
|
||||
|
||||
|
||||
Reference in new issue