feat: the x axis is relative to now, and an export carries both clocks

Three asked-for changes, one commit because they are one coordinate system.

The live axis is a fixed [-window, 0] with the newest sample at 0, so x reads
as an age and the labels stand still while the trace rolls under them. That
makes the display clock distinct from the stream clock for the first time, so
`ScopeModel::stream_at_x0()` becomes the single conversion between them
(`display_x = stream_t - stream_at_x0()` in all four modes) and a snapshot
carries its own origin in `EventSnapshot::x_offset`. The pause view is now
rebased like an event's, reversing an earlier deliberate choice: a frozen
absolute-stamped picture would sit a whole uptime right of a newest-relative
axis. That also fixed a latent bug, the export adding `trigger_time()` to a
*paused* view's stamps.

The status bar says how long you have been paused -- wall time, since the
producer never stops, through `format_elapsed()` so the field cannot widen.

The export writes two time columns: `time`, the axis as displayed, and
`abs_seconds`, the stream's own clock for the same sample. f64 seconds and
not the wire's integer, because `udps_frame_t::values` is a `const double*`
and the integer never exists in this process.

Cursors and measurement marks move in opposite directions under the rolling
axis, deliberately: a cursor is a position on screen and stays put, a mark
names a sample and travels with it. `App::measure_window` is stream-clocked
for a sharper reason -- a display-coordinate live window never moves, so the
"the window moved" recompute would never fire again.

Moves the deps/plotter pin to 58473db, which stops a time label's mantissa
reaching its own radix: a one-second tick differenced off a live axis read
`1e+3ms`.

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
This commit is contained in:
Martino FerrariandClaude Opus 4.6 committed 2026-10-05 21:49:12 +02:00
1 parent 2f4530c128
commit b313cac46e
18 files changed
+501 -145

No files matched your search

+9 -3
View File
@@ -6,9 +6,15 @@ Acquisition runs on its own thread and writes a ring buffer sized from <tt>--buf
the drawing thread reads whatever that ring holds when a frame starts, which is why a trace
never makes the window stutter.
The stream is the clock. Every time you read on screen is a timestamp the source sent, never
your machine's, so a stalled source freezes the view instead of scrolling it -- and a source
whose clock steps still gets the window you asked for.
The stream is the clock. Every interval you read on screen is measured between timestamps the
source sent, never your machine's, so a stalled source freezes the view instead of scrolling it
-- and a source whose clock steps still gets the window you asked for.
The time axis is <i>relative to now</i>. While streaming it is a fixed <tt>[-window .. 0]</tt>
with the newest sample at 0, so x reads as an age: <tt>-1.5s</tt> is a sample a second and a half
old. In trigger mode 0 is the event's edge instead, and a paused view keeps the ages it was
frozen with. The source's own clock is still there when you need it -- an export writes it as a
second column.
<b>How to reach it</b>