docs: the measures panel's frame is read by switch_on/reset_sensitive
The dump line's two new fields, and what either of them disagreeing with [stats-probe] on= means: a .ui that lost the widget, or the wiring to it. pane_rows is what proves the readout rows landed in the frame's measures_list.
This commit is contained in:
1 parent
d344361165
commit
07fcf61a70
1 file changed
+5
-2
@@ -196,7 +196,7 @@ Two lines of the self-check output are assertions in disguise:
|
|||||||
"the app placed them and they are on screen".
|
"the app placed them and they are on screen".
|
||||||
- `[measures-probe]` + the dump's `measure N: 'sig' type thr=..% above=D show=D -> ok|invalid value text=[..]
|
- `[measures-probe]` + the dump's `measure N: 'sig' type thr=..% above=D show=D -> ok|invalid value text=[..]
|
||||||
[duty=..] [marks=..]` and `measures pane: n=N revealed=D marks_shown=M pane_rows=R pane_w=W
|
[duty=..] [marks=..]` and `measures pane: n=N revealed=D marks_shown=M pane_rows=R pane_w=W
|
||||||
pane_h=H`
|
pane_h=H switch_on=X reset_sensitive=Y`
|
||||||
(stderr, `UDPSCOPE_PROBE_MEASURES_MS`) — adds one measurement of every type on the first
|
(stderr, `UDPSCOPE_PROBE_MEASURES_MS`) — adds one measurement of every type on the first
|
||||||
plottable signal and lets the tick compute them, so what it prints is what a user reads.
|
plottable signal and lets the tick compute them, so what it prints is what a user reads.
|
||||||
On the test stream's 1 Hz ±1 sine the values must be: average ≈ 0, `top` ≈ 0.64 and
|
On the test stream's 1 Hz ±1 sine the values must be: average ≈ 0, `top` ≈ 0.64 and
|
||||||
@@ -213,7 +213,10 @@ Two lines of the self-check output are assertions in disguise:
|
|||||||
*and* a marker at the first sample that reached it — two level marks at both extremes was
|
*and* a marker at the first sample that reached it — two level marks at both extremes was
|
||||||
the bug), `time:A,time:B` for pulse/period/frequency. `text=` is the pane's own string with
|
the bug), `time:A,time:B` for pulse/period/frequency. `text=` is the pane's own string with
|
||||||
its unit, so `frequency` must read `Hz` (not the signal's unit), `period`/`pulse duration`
|
its unit, so `frequency` must read `Hz` (not the signal's unit), `period`/`pulse duration`
|
||||||
seconds, and the rest the channel's unit. `marks_shown` counts two per shown measurement
|
seconds, and the rest the channel's unit. `switch_on` and `reset_sensitive` are the panel's *frame* read back: the switch widget against
|
||||||
|
`measure_stats_on`, which the code drives, and the Reset button that follows it. Either disagreeing with
|
||||||
|
`[stats-probe] on=` is a `.ui` that lost the widget, or lost the wiring to it; `pane_rows=R` is what
|
||||||
|
proves the readout rows landed in the frame's `measures_list` rather than nowhere. `marks_shown` counts two per shown measurement
|
||||||
(a min/max showing both its marks counts two of its own). `measures window:` is the
|
(a min/max showing both its marks counts two of its own). `measures window:` is the
|
||||||
timeliness assertion -- the window the numbers were computed over against the one on screen.
|
timeliness assertion -- the window the numbers were computed over against the one on screen.
|
||||||
**The reading that must hold is `marks_in_window=K/K`**: every *time* mark inside the window
|
**The reading that must hold is `marks_in_window=K/K`**: every *time* mark inside the window
|
||||||
|
|||||||
Reference in new issue