record (bo,"EC-GN-P01-GAF-GCPS:STAT-MANM") { field(DESC, "Manual Mode SW for GY1 GCPS") field(ONAM, "ON") field(PINI, "YES") field(SCAN, "Passive") field(VAL, "1") field(ZNAM, "OFF") } record (bo,"EC-GN-P01-GAF-GCPS:STAT-SIMM") { field(DESC, "GY1 GCPS Simulation Mode SW") field(ONAM, "YES") field(PINI, "YES") field(SCAN, "Passive") field(VAL, "0") field(ZNAM, "NO") } record (mbbi,"EC-GN-P01-GAF-GCPS:PSU2130-ACT-RB") { field(DESC, "GY1 GCPS read ACT") field(DTYP, "stream") field(FRST, "ZERO") field(FRSV, "NO_ALARM") field(FRVL, "4") field(INP, "@JASTEC-SCMPS.proto readActivity GC1") field(ONST, "SET") field(ONSV, "NO_ALARM") field(ONVL, "1") field(PINI, "YES") field(SCAN, "1 second") field(SIML, "EC-GN-P01-GAF-GCPS:STAT-SIMM") field(THST, "FLAT TOP") field(THSV, "NO_ALARM") field(THVL, "3") field(TWST, "DOWN") field(TWSV, "NO_ALARM") field(TWVL, "2") field(ZRST, "HOLD") field(ZRSV, "NO_ALARM") field(ZRVL, "0") } record (mbbo,"EC-GN-P01-GAF-GCPS:PSU2130-ACT-SP") { field(DESC, "GY1 GCPS set ACT") field(DTYP, "stream") field(ONST, "SET") field(ONSV, "NO_ALARM") field(ONVL, "1") field(OUT, "@JASTEC-SCMPS.proto setActivity GC1") field(PINI, "YES") field(SCAN, "Passive") field(SIML, "EC-GN-P01-GAF-GCPS:STAT-SIMM") field(TWST, "DOWN") field(TWSV, "NO_ALARM") field(TWVL, "2") field(ZRST, "HOLD") field(ZRSV, "NO_ALARM") field(ZRVL, "0") } record (mbbo,"EC-GN-P01-GAF-GCPS:PSU2130-ACT-SP-MI") { field(DESC, "GY1 GCPS ACT set to Marte") field(ONST, "SET") field(ONSV, "NO_ALARM") field(ONVL, "1") field(PINI, "NO") field(SCAN, "Passive") field(TWST, "DOWN") field(TWSV, "NO_ALARM") field(TWVL, "2") field(ZRST, "HOLD") field(ZRSV, "NO_ALARM") field(ZRVL, "0") } record (mbbo,"EC-GN-P01-GAF-GCPS:PSU2130-ACT-SP-MO") { field(DESC, "GY1 GCPS ACT Marte outputs") field(FLNK, "EC-GN-P01-GAF-GCPS:STAT-ACT-SP-CALC") field(ONST, "SET") field(ONSV, "NO_ALARM") field(ONVL, "1") field(PINI, "NO") field(SCAN, "Passive") field(TWST, "DOWN") field(TWSV, "NO_ALARM") field(TWVL, "2") field(ZRST, "HOLD") field(ZRSV, "NO_ALARM") field(ZRVL, "0") } record (ai,"EC-GN-P01-GAF-GCPS:PSU2130-CURR-MON") { field(DESC, "GY1 GCPS monitored current") field(DTYP, "stream") field(EGU, "A") field(HOPR, "125") field(INP, "@JASTEC-SCMPS.proto readMeasCurrent GC1") field(LOPR, "-125") field(PINI, "YES") field(PREC, "2") field(SCAN, "1 second") field(SIML, "EC-GN-P01-GAF-GCPS:STAT-SIMM") } record (waveform,"EC-GN-P01-GAF-GCPS:PSU2130-ERR") { field(DESC, "GY1 GCPS read error") field(DTYP, "stream") field(INP, "@JASTEC-SCMPS.proto readErrStat GC1") field(NELM, "15") field(PINI, "YES") field(SCAN, "1 second") field(SIML, "EC-GN-P01-GAF-GCPS:STAT-SIMM") } record (ai,"EC-GN-P01-GAF-GCPS:PSU2130-SWP-LIM") { field(DESC, "GY1 GCPS read sweep limit") field(DTYP, "stream") field(EGU, "A/min") field(HOPR, "99.99") field(INP, "@JASTEC-SCMPS.proto readSweepLim GC1") field(LOPR, "0.01") field(PINI, "YES") field(PREC, "2") field(SCAN, "1 second") field(SIML, "EC-GN-P01-GAF-GCPS:STAT-SIMM") } record (ai,"EC-GN-P01-GAF-GCPS:PSU2130-SWP-RB") { field(DESC, "GY1 GCPS read targ sweep rate") field(DTYP, "stream") field(EGU, "A/min") field(HOPR, "99.99") field(INP, "@JASTEC-SCMPS.proto readTargSweep GC1") field(LOPR, "0.01") field(PINI, "YES") field(PREC, "2") field(SCAN, "1 second") field(SIML, "EC-GN-P01-GAF-GCPS:STAT-SIMM") } record (ai,"EC-GN-P01-GAF-GCPS:PSU2130-TRG-CURR-RB") { field(DESC, "GY1 GCPS read target current") field(DTYP, "stream") field(EGU, "A") field(HOPR, "120") field(INP, "@JASTEC-SCMPS.proto readTargCurrent GC1") field(LOPR, "0") field(PINI, "YES") field(PREC, "2") field(SCAN, "1 second") field(SIML, "EC-GN-P01-GAF-GCPS:STAT-SIMM") } record (ao,"EC-GN-P01-GAF-GCPS:PSU2130-TRG-CURR-SET") { field(DESC, "GY1 GCPS set target current") field(DRVH, "120") field(DRVL, "0") field(DTYP, "stream") field(EGU, "A") field(FLNK, "EC-GN-P01-GAF-GCPS:PSU2130-ACT-SP") field(HOPR, "125") field(LOPR, "0") field(OUT, "@JASTEC-SCMPS.proto setCurrent GC1") field(PINI, "YES") field(PREC, "3") field(SCAN, "Passive") field(SIML, "EC-GN-P01-GAF-GCPS:STAT-SIMM") field(VAL, "0") } record (ao,"EC-GN-P01-GAF-GCPS:PSU2130-TRG-CURR-SET-MI") { field(DESC, "GY1 GCPS target current input to Marte") field(DRVH, "120") field(DRVL, "-120") field(EGU, "A") field(HOPR, "125") field(LOPR, "-125") field(PINI, "YES") field(PREC, "3") field(SCAN, "Passive") field(VAL, "0") } record (ao,"EC-GN-P01-GAF-GCPS:PSU2130-TRG-CURR-SET-MO") { field(DESC, "GY1 GCPS target current Marte outputs") field(DRVH, "120") field(DRVL, "-120") field(EGU, "A") field(FLNK, "EC-GN-P01-GAF-GCPS:STAT-TRG-CURR-SET-CALC") field(HOPR, "125") field(LOPR, "-125") field(PINI, "YES") field(PREC, "3") field(SCAN, "Passive") field(VAL, "0") } record (ao,"EC-GN-P01-GAF-GCPS:PSU2130-TRG-SWPR-SET") { field(DESC, "GY1 GCPS set target swwp rate") field(DRVH, "5.0") field(DRVL, "0.01") field(DTYP, "stream") field(EGU, "A/min") field(HOPR, "99.99") field(LOPR, "0.01") field(OUT, "@JASTEC-SCMPS.proto setSweep GC1") field(PINI, "YES") field(PREC, "2") field(SCAN, "Passive") field(SIML, "EC-GN-P01-GAF-GCPS:STAT-SIMM") field(VAL, "1") } record (ai,"EC-GN-P01-GAF-GCPS:PSU2130-VOLT-MON") { field(DESC, "GY1 GCPS monitored voltage") field(DTYP, "stream") field(EGU, "V") field(HOPR, "10") field(INP, "@JASTEC-SCMPS.proto readMeasVoltage GC1") field(LOPR, "-10") field(PINI, "YES") field(PREC, "2") field(SCAN, "1 second") field(SIML, "EC-GN-P01-GAF-GCPS:STAT-SIMM") } record (calcout,"EC-GN-P01-GAF-GCPS:STAT-ACT-SP-CALC") { field(CALC, "A") field(DESC, "GCPS#1 state set by Marte") field(INPA, "EC-GN-P01-GAF-GCPS:PSU2130-ACT-SP-MO") field(OOPT, "On Change") field(OUT, "EC-GN-P01-GAF-GCPS:PSU2130-ACT-SP PP") field(SCAN, "Passive") } record (waveform,"EC-GN-P01-GAF-GCPS:STAT-PREP-WF") { field(DESC, "GY1 GCPS prepro schedule") field(EGU, "A") field(FTVL, "FLOAT") field(NELM, "8000") field(PINI, "NO") field(PREC, "2") field(SCAN, "Passive") } record (calcout,"EC-GN-P01-GAF-GCPS:STAT-TRG-CURR-SET-CALC") { field(CALC, "A") field(DESC, "GCPS#1 current set by Marte") field(INPA, "EC-GN-P01-GAF-GCPS:PSU2130-TRG-CURR-SET-MO") field(OOPT, "On Change") field(OUT, "EC-GN-P01-GAF-GCPS:PSU2130-TRG-CURR-SET PP") field(SCAN, "Passive") }