from org.csstudio.opibuilder.scriptUtil import PVUtil
|
||||
from org.csstudio.opibuilder.scriptUtil import ColorFontUtil
|
||||
# from org.csstudio.opibuilder.scriptUtil import ConsoleUtil
|
||||
|
||||
table = widget.getTable()
|
||||
|
||||
#Fill PV Name only once
|
||||
if widget.getVar("firstTime") == None:
|
||||
widget.setVar("firstTime", True)
|
||||
i=0
|
||||
# Fill table only with non EGU pv's
|
||||
for pv in pvs:
|
||||
# earlier when by default pv.getName() was giving name with 'epics://' prefix. Ripping it off before showing was done below
|
||||
table.setCellText(i, 0, pv.getName().strip())
|
||||
if not pv.isConnected():
|
||||
table.setCellText(i/2, 1, "Disconnected")
|
||||
i+=1
|
||||
# Based on value of macro SHOW_PLC_IOC, enable visibility of PLCIOCDetailsTable
|
||||
if widget.getPropertyValue("name") == 'PLCIOCDetailsTable':
|
||||
if display.getMacroValue("SHOW_PLC_IOC") == "true":
|
||||
widget.setPropertyValue("visible", "true")
|
||||
display.getWidget("PLCIOCDetailsLabel").setPropertyValue("visible", "true")
|
||||
|
||||
#find index of the trigger PV
|
||||
i=0
|
||||
while triggerPV != pvs[i]:
|
||||
i+=1
|
||||
|
||||
pvValue = PVUtil.getString(triggerPV).strip();
|
||||
eugValue = table.getCellText(i, 4);
|
||||
if eugValue != "":
|
||||
pvValue = pvValue+" "+eugValue;
|
||||
table.setCellText(i, 1, pvValue)
|
||||
table.setCellText(i, 2, PVUtil.getStatus(triggerPV).strip())
|
||||
table.setCellText(i, 3, PVUtil.getSeverityString(triggerPV).strip())
|
||||
|
||||
s = PVUtil.getSeverity(triggerPV)
|
||||
|
||||
color = ColorFontUtil.WHITE
|
||||
if s == 0:
|
||||
color = ColorFontUtil.GREEN
|
||||
elif s == 1:
|
||||
color = ColorFontUtil.RED
|
||||
elif s == 2:
|
||||
color = ColorFontUtil.YELLOW
|
||||
elif s == 3:
|
||||
color = ColorFontUtil.PINK
|
||||
|
||||
table.setCellBackground(i, 3, color)
|
||||
Reference in New Issue